Remote Die Box
Die Protection Sensor Interface Remote Die Box
The six (6) channel remote die box allows you to quickly change out the die sensors by using either plug connectors or Banana jacks. Provides +24VDC power to active sensors and monitors the status (PNP or NPN). Part number 53-450 six (6) channel Remote Die Box includes individual channel indicators, 45’ quick disconnect cable (12 conductor) minimizes wiring installation time and power supply included to power sensors – 24VDC at 2.5 AMP.
53-450 Six (6) channel Remote Die Box The six (6) channel remote die box allows you to quickly change out the die sensors by using either plug connectors or Banana jacks. Provides +24VDC power to active sensors and monitors the status (PNP or NPN). Pin Wire Color Description Enclosure: NEMA 12, 13, IP54 painted steel (blue) Enclosure Dimensions: 8” (203mm) Height RED = PNP GREEN = NPN Banana Jack: Passive GND sensors when used you must jumper Pin 1 to 3 on Lumberg receptacle (female) (i.e. NPN only) Pin Description
Includes:
Individual Channel Indicators
Cable – 45’ quick disconnect (12 conductor) minimizes wiring installation time
Power Supply included to power sensors – 24VDC at 2.5 AMP
1 BRN 120VAC L input
2 N/C
3 RED Earth Ground
4 ORG +24v out (from power supply)
5 YEL +24v out (from power supply)
6 GRN Die #6 output
7 Shield Case Ground
8 N/C
9 BLU Die #5 output
10 VLT Ground
11 GRY Die #2 output
12 WHT Die #1 output
13 BLK Die #3 output
14 BK/WT Die #4 output
15 RD/WT 120VAC N input
16 N/C
6” (152mm) Wide
3.5” (89mm) Deep
1 Jumper to Pin 3 if NPN, to Pin 4 if PNP
2 Sensor Output (NPN or PNP)
3 +24VDC from Die Box power supply
4 Ground from Die Box power supply